As per Arber333:
As per Arber333:
<blockquote>
<blockquote>
Also from Volt pack you can salvage 2 powerfull contactors. P/N AEV14012 it is rated for 120A continuously and 400A for a short burst. <s>This means they had to use one of theese on + line and another on - side. Together you get 240A rating for system with 800A for a burst of power.
Also from Volt pack you can salvage 2 powerfull contactors. P/N AEV14012 it is rated for 120A continuously and 400A for a short burst. This means they had to use one of theese on + line and another on - side. When paralleling the contactors you get 240A rating for system with 800A for a burst of power.
Contactor pulls 0.5A when active.</s>
 
</blockquote>Edit Johannes: putting relays in series (i.e. one on B+ one on B-) does not double their current carrying capacity!
Contactor pulls 0.5A when active.
</blockquote>
 


Mouser lists as obsolete with no replacement:<br>
Mouser lists as obsolete with no replacement:<br>

Latest revision as of 10:54, 13 May 2024

Panasonic AEV14012.jpg
As per Arber333:

Also from Volt pack you can salvage 2 powerfull contactors. P/N AEV14012 it is rated for 120A continuously and 400A for a short burst. This means they had to use one of theese on + line and another on - side. When paralleling the contactors you get 240A rating for system with 800A for a burst of power.

Contactor pulls 0.5A when active.


Mouser lists as obsolete with no replacement:
https://www.mouser.com/ProductDetail/Panasonic-Industrial-Devices/AEV31012?qs=%2Fha2pyFaduhQtRGmPu6CHKnpAO9pZACcsMnCfvY8GwI%3D