Chevrolet Volt Coolant Valve: Difference between revisions
Jump to navigation
Jump to search
(Created page with " Pin1 – enable 12V<br> Pin2 – signal feedback<br> Pin3 – PWM control<br> Pin4 – GND<br> Pin5 - 12V supply<br> {| class="wikitable" |+ |thumb|Coolant Heater Control Valve |}") |
No edit summary |
||
Line 1: | Line 1: | ||
Chevrolet Volt Heater control valve is a 3 way valve that supplies heater system with fluid either from HV heater side or from ICE engine side.<br> | |||
Control is done by 5V signal.<br> | |||
This control valve is located in the middle left side of the hood.<br> | |||
[[File:Coolant Heater Control Valve position.png|thumb|Coolant Heater Control Valve position]] | |||
Pin1 – 12V<br> | |||
Pin2 – Solenoid control signal<br> | |||
Pin3 – 5V reference<br> | |||
Pin4 – Solenoid Position signal<br> | |||
Pin5 - Low reference <br> | |||
Pin6 - GND<br> | |||
[[File:Coolant control valve.jpg|thumb|Coolant control valve]] | |||
{| class="wikitable" | {| class="wikitable" |
Revision as of 10:28, 23 September 2024
Chevrolet Volt Heater control valve is a 3 way valve that supplies heater system with fluid either from HV heater side or from ICE engine side.
Control is done by 5V signal.
This control valve is located in the middle left side of the hood.
Pin1 – 12V
Pin2 – Solenoid control signal
Pin3 – 5V reference
Pin4 – Solenoid Position signal
Pin5 - Low reference
Pin6 - GND