Toyota Inverter Clocked Serial Interface Protocol: Difference between revisions

From openinverter.org wiki
Jump to navigation Jump to search
Line 8: Line 8:
* MTH Inverter to Hybrid controller data frame
* MTH Inverter to Hybrid controller data frame


The number of bytes sent/received during a transfer will depend on the model of inverter, the table bel at 500kbpsow outlines the number of bytes for the different inverter models:-
[[File:HybridFrameSizes.png|thumb|The number of bytes sent/received during a transfer will depend on the model of inverter, the table above outlines the number of bytes for the different inverter models.]]


Bus Transfer Sequence starts with the REQ line changing state     
Bus Transfer Sequence starts with the REQ line changing state     

Revision as of 21:21, 7 July 2021

This page is dedicated to use of Toyota inverters (Lexus / Camary / Gen3 Prius / Auris / Yaris) unmodified via the serial protocol (REQ, CLK, HTM, MTH). This page also contains wiring and connector information for the various models of Toyota Inverters.

Toyota Protocol

  • REQ Request line from hybrid controller to Inverter
  • CLK Clock signal from hybrid controller to Inverter (Constant 500KHz)
  • HTM Hybrid controller to Inverter data frame
  • MTH Inverter to Hybrid controller data frame
The number of bytes sent/received during a transfer will depend on the model of inverter, the table above outlines the number of bytes for the different inverter models.

Bus Transfer Sequence starts with the REQ line changing state

Toyota Serial example waveforms

Data logging Toyota Serial Protocol











Toyota Inverter Connectors

Lexus GS450 / Camry


Gen3 Pruis / Auris / Yaris