Chademo with Zombieverter: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
GregFordyce (talk | contribs) (Added solder jumper settings for Chademo) |
||
Line 6: | Line 6: | ||
* 2 Contactors for Chademo use | * 2 Contactors for Chademo use | ||
* Zombie VCU | * Zombie VCU | ||
* Jumper settings as per the instructions on the back of the board. | * Jumper settings for HS CAN3. Solder SJ6, SJ7, SJ8 and SJ9, as per the instructions on the back of the board. Additionally Solder SJ5 and SJ10 for CAN3 Termination. | ||
<gallery> | |||
File:ChademoJumpers.jpg | |||
</gallery> | |||
* Chademo set to Charge Control interface in the UI | * Chademo set to Charge Control interface in the UI | ||
* An output set to ChaDeMoAl | * An output set to ChaDeMoAl |
Revision as of 19:27, 21 September 2024
https://www.youtube.com/watch?v=zuPvgzQt6XQ
Requirements
- Chademo Socket
- 2 Contactors for Chademo use
- Zombie VCU
- Jumper settings for HS CAN3. Solder SJ6, SJ7, SJ8 and SJ9, as per the instructions on the back of the board. Additionally Solder SJ5 and SJ10 for CAN3 Termination.
- Chademo set to Charge Control interface in the UI
- An output set to ChaDeMoAl
- GP12VINFuct set to DCFCRequest in the UI