Mitsubishi Outlander Water Heater: Difference between revisions
Jump to navigation
Jump to search
Line 15: | Line 15: | ||
== Can Messages from Heater == | == Can Messages from Heater == | ||
When 12v is connected, without HV, the following messages are broadcast: | When 12v is connected, without HV, the following messages are broadcast: | ||
0x398 ID 00 09 00 3B 3B 00 00 00 at 100ms | 0x398 ID 00 09 00 3B 3B 00 00 00 at 100ms byte 3 seems to be water temperature, byte 4 device temperature | ||
0x630 ID 00 00 00 00 00 00 00 00 at 500ms | 0x630 ID 00 00 00 00 00 00 00 00 at 500ms |
Revision as of 15:25, 11 October 2021
The Outlander PHEV has an optional electric water heater. This unit appears to be a 3rd generation http://www.mhi.co.jp/technology/review/pdf/e542/e542057.pdf. Specified as a 4kw unit.
Low Voltage Pinout
Top row, yellow is 12+, black is GND.
Bottom row, under the yellow is Can H and under GND is Can L
The mating connector looks to be Sumitomo 6189-0126 https://www.auto-click.co.uk/6189-0126?search=90980-10942
High Voltage Pinout
Can Messages from Heater
When 12v is connected, without HV, the following messages are broadcast:
0x398 ID 00 09 00 3B 3B 00 00 00 at 100ms byte 3 seems to be water temperature, byte 4 device temperature
0x630 ID 00 00 00 00 00 00 00 00 at 500ms
0x062D ID 00 00 00 00 00 00 00 00 at 500ms
0x06BD ID 00 00 00 00 00 00 00 00 at 500ms
When HV is connected 0x398 changes to the message below.
0x398 ID 00 00 00 3B 3B 00 00 00 at 100ms
Control Can Messages
Not yet discovered.