(Created page with "I reviewed Ampera manual and came to a page describing connector and PWM activate pin. I applied 1kHz signal from makeshift 5V generator at 50% – 75% duty and pump responded and spooled up at low to medium speed. Wires in connector need to be connected according to this diagram. <br> |thumb|Coolant Pump Wiring")
 
No edit summary
Line 1: Line 1:
I reviewed Ampera manual and came to a page describing connector and PWM activate pin. I applied 1kHz signal from makeshift 5V generator at 50% – 75% duty and pump responded and spooled up at low to medium speed. Wires in connector need to be connected according to this diagram. <br>
I reviewed Ampera manual and came to a page describing connector and PWM activate pin. I applied 1kHz signal from makeshift 5V generator at 50% – 75% duty and pump responded and spooled up at low to medium speed. Wires in connector need to be connected according to this diagram. <br>
 
[[File:Coolant pump wiring.png|thumb|Coolant Pump Wiring]]
|[[File:Coolant pump wiring.png|thumb|Coolant Pump Wiring]]

Revision as of 08:18, 23 September 2024

I reviewed Ampera manual and came to a page describing connector and PWM activate pin. I applied 1kHz signal from makeshift 5V generator at 50% – 75% duty and pump responded and spooled up at low to medium speed. Wires in connector need to be connected according to this diagram.

Coolant Pump Wiring