Line 7: | Line 7: | ||
=== wiring the zombiverter to the leaf harness === | === wiring the zombiverter to the leaf harness === | ||
the motor/inverter and PDM each use there own canbus | the motor/inverter and PDM each use there own canbus. they both can be used independent of one another with the zombieverter. | ||
==== INVERTER to zombie wiring: ==== | |||
EV SYSTEM CAN-H (pin14) to CAN EXT H (pin 28) | EV SYSTEM CAN-H (pin14) to CAN EXT H (pin 28) | ||
EV SYSTEM CAN-L (pin15) to CAN EXT L (pin 27) | EV SYSTEM CAN-L (pin15) to CAN EXT L (pin 27) | ||
==== PDM to zombie wiring: ==== | |||
PDM to zombie wiring: | |||
Revision as of 16:30, 24 October 2023
setting up a leaf stack with the zombiverter VCU
the full leaf stack ( motor/inverter, pdm (charger, dcdc, hvjb)) can be controlled with the zombieverter VCU
all you need is 12v and CANbus
wiring
wiring the zombiverter to the leaf harness
the motor/inverter and PDM each use there own canbus. they both can be used independent of one another with the zombieverter.
INVERTER to zombie wiring:
EV SYSTEM CAN-H (pin14) to CAN EXT H (pin 28)
EV SYSTEM CAN-L (pin15) to CAN EXT L (pin 27)
PDM to zombie wiring:
CAN H (ev system) pin 27 to CAN EXT 2 H
CAN L (ev system) pin 11 to CAN EXT 2 L
EVSE CONNECTING SIGNAL pin 29 to
EVSE COMMUNICATION (PWM) pin 30 to