Leaf stack with zombiverter: Difference between revisions

From openinverter.org wiki
Jump to navigation Jump to search
No edit summary
 
(30 intermediate revisions by 6 users not shown)
Line 1: Line 1:
=== setting up a leaf stack with the zombiverter VCU ===
the full leaf stack ( motor/inverter, pdm (charger, dcdc, hvjb)) can be controlled with the zombieverter VCU


all you need is 12v and CANbus


== wiring ==
<nowiki>*</nowiki>this page is a work in progress and may not be fully accurate or up to date.


=== wiring the zombiverter to the leaf harness ===
=== Setting up a leaf stack with the zombiverter VCU ===
the motor/inverter and PDM each use there own canbus
The full leaf stack ( motor/inverter, pdm (charger, dcdc, hvjb)) can be controlled with the zombieverter VCU.


inverter to zombie wiring:
All you need is 12v+, enable, and CANbus.
EV SYSTEM CAN-H (pin14)  to  CAN EXT H (pin 28)


EV SYSTEM CAN-L (pin15)  to  CAN EXT L (pin 27)




PDM to zombie wiring:
''As of software release [https://github.com/damienmaguire/Stm32-vcu/releases/tag/2.20a V2.20A,] the IVT shunt used for UDC data is no longer required for precharge.''


''The leaf Inverter itself'' can supply UDC data for precharge (set the Shunt Type = 0)


CAN H (ev system) pin 27 to CAN EXT 2 H
the PDM is not needed for UDC data. 


CAN L (ev system) pin 11 to CAN EXT 2 L
The leaf motor and inverter do not require the PDM to run with the zombieverter, or for UDC measurements.  
== Wiring ==
[[File:Zombi-leaf-wiringv3.jpg|thumb|568x568px]]
=== Wiring the zombiverter to the leaf harness ===
===== Pinout =====
{| class="wikitable"
! colspan="2" |Description
!Zombieverter Pin
!PDM pin
!inverter pin
|-
|
|
|
|
|
|-
| +12V
|Permanent 12v+
|56
|18
|46, 48
|-
|Gnd
|permanent 12v -
|55
|pdm case
|47, 49
|-
|Fwd signal
|Forward
|54
|
|
|-
|Rev signal
|Reverse
|53
|
|
|-
|momentary 12V
|Start signal
|52
|
|
|-
|Brake signal
|Brake Input
|49
|
|
|-
| +5V
|Throttle
|48
|
|
|-
|Throttle signal 1
|Throttle signal 1
|47
|
|
|-
|Throttle signal 2
|Throttle signal 2
|46
|
|
|-
|Throttle Gnd
|Throttle Gnd
|45
|
|
|-
|Precharge Contactor LS Switch
|Negative lead from precharge contactor
|34
|
|
|-
|Main Contactor LS Switch
|Negative lead from main contactor
|33
|
|
|-
|enable relay
|switches enable relay
|32
|16
|42
|-
|Neg Contactor LS Switch
|Negative lead from negative contactor
|31
|
|
|-
|CANEXTH
|Can 1 High
|28
|27
|14
|-
|CANEXTL
|Can 1 Low
|27
|11
|15
|-
|T15
|Ignition 12V in
|15
|
|
|-
|proximity pilot
|pp for charge port
|
|29
|
|-
|control pilot
|cp for charge port
|
|30
|
|}
[[File:Leaf Inverter connections.png|left|thumb|818x818px|Leaf Inverter terminal layout and physical values for signals]]






[[File:ZombieVerter VCU V1 cable side pinout2.jpg|thumb|zombiverter pinout|left|602x602px]]
 
[[File:Leaf inverter pinout.jpg|thumb|leaf inverter connector pinout|560x560px]]
 
[[File:PDM PINOUT.png|thumb|pinout of the pdm|716x716px]]
 
[[File:Leaf resolver pinout.png|thumb|em57 resolver pinout]]
[[File:Leaf PDM Connections.png|thumb|1120x1120px|Leaf PDM connector pinout and physical values. This seems to apply to 2013-2017 Leaf. Check what you have before blindly making any connections.]]
 
 
 
 
[[File:PDM PINOUT.png|thumb|737x737px]]
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
[[File:Leafbattery36.png|thumb|638x638px]]
 
 
[[Chademo with Zombieverter|Chademo to Zombiverter:]]
 
Details can be found on a [[Chademo with Zombieverter|dedicated page.]]<br />
chademo connector:
 
HV contactor coil + pin 2 to GP 12v input
 
HV contactor coil - pin 10
 
pin 1 to ground
 
CAN H pin 8 to CAN EXT 3 H
 
CAN L pin 9 to CAN EXT 3 L
 
pin 4 to GP out

Latest revision as of 14:57, 10 April 2025


*this page is a work in progress and may not be fully accurate or up to date.

Setting up a leaf stack with the zombiverter VCU

The full leaf stack ( motor/inverter, pdm (charger, dcdc, hvjb)) can be controlled with the zombieverter VCU.

All you need is 12v+, enable, and CANbus.


As of software release V2.20A, the IVT shunt used for UDC data is no longer required for precharge.

The leaf Inverter itself can supply UDC data for precharge (set the Shunt Type = 0)

the PDM is not needed for UDC data.

The leaf motor and inverter do not require the PDM to run with the zombieverter, or for UDC measurements.

Wiring

Zombi-leaf-wiringv3.jpg

Wiring the zombiverter to the leaf harness

Pinout
Description Zombieverter Pin PDM pin inverter pin
+12V Permanent 12v+ 56 18 46, 48
Gnd permanent 12v - 55 pdm case 47, 49
Fwd signal Forward 54
Rev signal Reverse 53
momentary 12V Start signal 52
Brake signal Brake Input 49
+5V Throttle 48
Throttle signal 1 Throttle signal 1 47
Throttle signal 2 Throttle signal 2 46
Throttle Gnd Throttle Gnd 45
Precharge Contactor LS Switch Negative lead from precharge contactor 34
Main Contactor LS Switch Negative lead from main contactor 33
enable relay switches enable relay 32 16 42
Neg Contactor LS Switch Negative lead from negative contactor 31
CANEXTH Can 1 High 28 27 14
CANEXTL Can 1 Low 27 11 15
T15 Ignition 12V in 15
proximity pilot pp for charge port 29
control pilot cp for charge port 30
Leaf Inverter terminal layout and physical values for signals




Leaf PDM connector pinout and physical values. This seems to apply to 2013-2017 Leaf. Check what you have before blindly making any connections.



PDM PINOUT.png













Leafbattery36.png


Chademo to Zombiverter:

Details can be found on a dedicated page.
chademo connector:

HV contactor coil + pin 2 to GP 12v input

HV contactor coil - pin 10

pin 1 to ground

CAN H pin 8 to CAN EXT 3 H

CAN L pin 9 to CAN EXT 3 L

pin 4 to GP out